Quantum-data 801GC Instrukcja Użytkownika Strona 232

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 231
6-106 Chapter 6: Programming
Model 801GC, 801GF & 801GX¥Rev. A
CSPP Composite Sync Pulse Polarity
Classification: Format parameter setting
Command Syntax: CSPP <polarity>
Limits: <polarity>
0 = active-low (negative going pulse)
1 = active-high (positive going pulse)
Query Syntax: CSPP?
Query Response: <polarity>
Description: The CSPP command establishes the logic sense of the digital
composite sync output. The CSPP? query returns the current
setting of CSPP.
Other Required Cmds: In order to use digital composite sync, it must be gated on with
the CSPG command and selected with the SSST command. The
FMTU command instructs the generator to use the new setting.
The ALLU command updates hardware to the new setting and
redraws the test image.
Example: CSPG 1 // Enable dig comp sync in
// buffer
CSPP 1 // Select active hi in buffer
SSST 2 // Choose digital comp sync type
// in buffer
FMTU // Update hardware to current
// buffer contents
Przeglądanie stron 231
1 2 ... 227 228 229 230 231 232 233 234 235 236 237 ... 355 356

Komentarze do niniejszej Instrukcji

Brak uwag