Video Test Generator User Guide 453
NLNK
Number of digital LiNKs
Class Format parameter setting - Digital video signal
Description Determines the number of links used by the LVDI digital outputs on generators that
support LVDI outputs. The NLNK? query returns the current setting of NLNK.
Command syntax NLNK links
links integer
0 = Default, let the generator decide
1 = Single link
2 = Dual link
Query syntax NLNK?
Query response links
Other required
commands
The FMTU command instructs the generator to use the new setting. The ALLU command
updates hardware to the new setting and redraws the test image.
Example
NLNK 2; FMTU